ICFS-Plus: Actuarial Software for the Property and Causality Insurance Industry

Known Problems with ICRFS-Plus™ 10.1

The following list contains the major problems we have been notified of in installing and running ICRFS-Plus™ 10.1, together with fixes. For troubleshooting support relating to ICRFS-Plus™ 10.0, click here.


Please contact support@insureware.com if you need any further help.


Errors are classified by when they appear: Installation Errors, Errors Launching ICRFS-Plus, Errors Opening a Database, Errors Opening PTF, Errors Closing ICRFS-Plus and Miscellaneous Bugs. Click on the error graphic to go to the fix.


See Updates for any new versions of utilities or patches.


Errors Launching ICRFS-Plus






Errors Opening a Database












Errors Closing ICRFS-Plus


Installation Errors

I1. Problems have been encountered when Permissions have been changed on the registry or Temp directory. Ensure that the account you are using for installation has full access rights to the registry and Temp directory.


Errors Running an ICRFS-Plus Licence File

L1. Error message running an ICRFS-Plus licence "Problem in updating registry. Please contact Insureware".


You need to log on to your computer with administrator rights to run an ICRFS-Plus licence file.


Errors Launching ICRFS-Plus

L1. Error message on starting ICRFS "Error #101: Your computer is not licensed to run ICRFS".

Check that the program "licence" (supplied on a floppy disk or CD at the start of the current licence period) has been run. If it has been run, record any message produced by the licence program and send it to Insureware.


L2. Error message on starting ICRFS "Error #103: ... Your computer is not licensed to run ICRFS".


Check that the label on the licence floppy or CD matches the label on the sentinel key. If it does, please contact Insureware.


This problem has also been seen when the sentinel key has been damaged by repeated removal. If you have another sentinel key, check whether the program will launch with the other sentinel key.


L3. Error message on starting ICRFS "Check the Sentinel key.".


Check that the sentinel key is in the parallel port or USB port.


This error can be caused by an incompatibility of the sentinel key driver and the parallel port settings, on Windows XP or 2000, particularly on Toshiba laptops. The internal settings of the computer may need to be changed. Alternatively, a USB sentinel key can be supplied. Please contact Insureware for assistance.


This problem has also been seen when the sentinel key has been damaged by repeated removal. If you have another sentinel key, check whether the program will launch with the other sentinel key.


Errors Opening a Database

O1. Error message on opening an Interbase database: "Database error: Unknown database".


Check that InterbaseForICRFS or Interbase 5.6 has been installed.


This can occur if Interbase 6 or 7 has been installed by some other application. Please check which version of Interbase is installed and contact Insureware.


Occasionally you may also get this message if ICRFS-Plus™ is launched immediately after restarting, if the required system services have not yet started up. Wait for a moment and try to open the database again.


O2. Error message on creating an Interbase database: "Database error: General SQL error".


This can occur if Interbase 7 has been installed by some other application. Please check which version of Interbase is installed and contact Insureware.


O3. Error message on opening or creating an Access database: "Database error: ADO could not find the specified provider".


Choose the option Install Access Components for ICRFS on the Custom screen of the ICRFS-Plus™ 10 installation CD.


O4. Error message on opening an Interbase database: "Unknown user name or password. unavailable database".


Check that InterbaseForICRFS or Interbase 5.6 has been installed.


This can occur on Windows 98 after installation. Restart the computer and try again.


Occasionally you may also get this message if ICRFS-Plus™ is launched immediately after restarting, if the required system services have not yet started up. Wait for a moment and try to open the database again.


O5. Error message on creating or opening an Interbase database: "Database error: Vendor initialization failed. Cannot load an IDAPI service library. File: GDS32.DLL Alias: theDB_1".


Check that InterbaseForICRFS or Interbase 5.6 has been installed.


This can occur if Interbase 6 or 7 has been installed by some other application. Please check which version of Interbase is installed and contact Insureware.


Occasionally you may also get this message if ICRFS-Plus™ is launched immediately after restarting, if the required system services have not yet started up. Wait for a moment and try to open the database again.


06. Database Error. General SQL Error. Check the username and password are correct. If you are using a non-default username and/or password please download patch 3 and see the readme.txt file for installation instructions.

Errors Opening PTF

P1. Error message on opening PTF: "External exception C000001D".


This can occur on Windows NT or computers with non-Intel processors. Run ICRFS-Plus™ and choose the menu option Options->Modelling Preferences and deselect Use Intel SPL.


Errors Closing ICRFS

C1. Error message on closing ICRFS after using an Access database: "This program has performed an illegal operation and will be shut down".


This can occur sometimes after using Access databases on Windows 98. This error is a result of third party software and there is no fix for it, but it has no known side-effects.


Miscellaneous Bugs

B1. Model files can not be saved in PCE or FL. Solution: download and install patch 3


B6. On Windows 98, opening too many windows can cause the operating system to run out of resources. This is likely to happen in MPTF if the composite dataset contains more than about 5 datasets.


Updates and Patches

ICRFS-Plus Patch 3 addresses the following issues and includes several enhancements.


1. Databases with non-default username and password could not be opened.

2. Databases with non-default username and password could not be used in COM.

3. Discount rates were sometimes not saved correctly in a forecast setup: if the number of future development periods or the number of future accident periods were increased after setting or editing the discount rates table, when the forecast setup was saved, the discount rates were set to the value in the discount rates cell instead of in the table.

4. Model files could not be saved in PCE and FL.

5. The FL forecast table was not correctly refreshed after a second forecast.


It also contains the following enhancements to 10.1:


1. In COM, the IForecastSetup interface has had a property useInflationDiscount added so that Inflation and Discount factors can be switched on or off in a forecast. Documentation for this property is given in UsrguidePartIIPatch1.pdf.

2. If there is more than one PLR or NCCR triangle in a triangle group, the required pair can be run in the FL module by setting one as the associated triangle on the other's dataset. For example, the dataset PLR(I) could be associated with a triangle NCCR(I). Note that the Ultimate Claims must be assigned as an exposure to the dataset PLR(I) in this case. Dataset PLR(I) must be selected before you click on the FL tab.

Note: the associated triangle MUST be incremental.

3. Negative numbers can now be entered in the FL Average, percentage Increase, and Forecast Factor tables.


Download patch 3 here and view the readme.txt file for installation instructions.